AccuPower® RocketScript™ Cycle RT PreMix


Amplify your cDNAs and your success with unsurpassed thermostability and sensitivity

AccuPower® RocketScript™ Cycle RT PreMix contains Bioneer’s exclusive M-MLV based thermostable reverse transcriptase
(RTase), RocketScript™. Conditions are optimized for Bioneer’s Cyclic Temperature Reverse Transcription (CTRT; patent pending) in a PreMix form.

Native M-MLV RTase has maximum activity at relatively low temperatures (42°C), causing several problems in reverse
transcription of RNA molecules with complex secondary structure.
AccuPower® RocketScript™ Cycle RT PreMix has thermostable activity across a wide temperature range, (42°C – 70°C),
allowing efficient cDNA synthesis from virtually any RNA.
The lyophilized PreMix contains all components necessary for a successful CTRT reaction, including RTase, RNase inhibitor and buffer components. Just add template RNA, primers and water, and the RT reaction is ready to go.


Schematic representation of the 5’UTR of a gene, with complex secondary structure, at three different temperatures.
Note that RocketScript™ shows full activity at 70°C allowing it to synthesize the complete gene sequence where M-MLV and other Reverse Transcriptase's fail.
 

Features and Benefits 

  • Thermostable Activity: RocketScript™ is able to perform reverse transcription reactions throughout a wide range of temperatures from 42°C to 70°C.
  • Enhanced Performance: RocketScript™ has enhanced performance to handle both high and low input RNA concentrations as well as short and long RT target sizes.
  • Easy-to-use: The product contains the enzyme itself, plus RNase inhibitors and all other components necessary for the best reverse transcription results in the tube.
  • Reproducibility: Bioneer's strict quality controlled production system ensures that your results will be reproducible experiment after experiment.
  • Convenient: Just add template and primers and start your reaction. dNTPs, buffer and enzyme are provided.
  • Stability: Stable at room temperature for a month one year at 4°C and for 2 years in a -20°C freezer
  • RNase, DNase and Proteinase-free: Ensures the integrity of your samples.
  • Broad range of working temperatures: For RNAs that are G:C rich or significant secondary structure
  • Stable for 2 years at -20°C: Long shelf life
]]>
Specifications

5' to 3' exonuclease: No
3' to 5' exonuclease: No
3’ – A Overhang: No
Fragment Size: Up to 10 kb

 

Application

- First-strand synthesis of cDNA from RNA molecules (Reverse Transcription)
- RT-PCR
- Random priming reaction
- Library construction
- Probe labeling
- mRNA 5' end mapping by primer extension analysis
- Real time PCR

 

Experimental data

Figure 1. Comparison of amplification efficiency between AccuPower® RocketScript™ Cycle RT PreMix and competitors’ RTases
(a) Sensitivity test
Primer set: Human TFRC set
Lane M: 1 kb DNA Ladder
Lane1: 100 ng Human total RNA from HeLa cell
Lane 2: 10 ng Human total RNA from HeLa cell
Lane3: 1 ng Human total RNA from HeLa cell
Lane4: 100 pg Human total RNA from HeLa cell
RT reaction condition is performed according to each manufacturer’s recommendations

(b) Full-Length cDNA synthesis test
RT reactions were performed according to each manufacturer’s recommendation. All cDNAs were amplified with AccuPower® Hotstart PCR Premix (K-5050) from Bioneer
Note: Competitor products show inhibition at high input concentrations of total RNA
Lane 1: 1 ug Human total RNA from HeLa cell
Lane 2: 100 ng Human total RNA from HeLa cell
Lane 3: 10 ng Human total RNA from HeLa cell


Figure 2. Complex RNA amplification results of RocketScript™ Cycle RT PreMix
Each target gene was amplified after performing reverse transcription with AccuPower® RocketScript™ Cycle RT PreMix.
Reverse transcription conditions: Conventional 1 hr incubation at 42°C, 50°C, or 60°C, deactivation at 95°C for 5 min
A: M-MLV Reverse Transcriptase
B: AccuPower® RocketScript™ Cycle RT PreMix with Oligo (dT)20
Lane 1: 100 ng Human total RNA from HeLa cell
Lane 2: 10 ng Human total RNA from HeLa cell
 

Concentration (copies/rxn) FTRT (Ct) CTRT with 1 cycle (Ct) CTRT with 10 cycles (Ct)
10,000 19.46 18.77 18.51
1,000 24.11 24.04 22.93
100 29.78 28.35 28.19
10 32.87 33.00 31.05
Figure 3. Low copy species enrichment by cycle.
Comparing FTRT (Fixed Temperature Reverse Transcription) to 1 and 10 cycle(s) of CTRT reveal progressive improvement in detected cDNA yield as input copies decrease.

FTRT: 60 min incubation at 50°C followed by 5 min deactivation at 95°C
CTRT: Cycles of 37°C annealing 10 sec, 50°C cDNA synthesis 4 min, 55°C secondary structure melting and cDNA synthesis 30 sec
Primer set: Human GAPDH
Human Total RNA from HeLa cells
qPCR with AccuPower® GreenStar™ qPCR PreMix (K-6210)


Figure 4. Amplification comparison by cycle

FTRT (Fixed Temperature Reverse Transcription) conditions:

Step Temperature Time No. of Cycles
dT20
cDNA synthesis 50°C 60 min 1
Heat inactivation 95°C 5 min 1

CTRT (Cyclic Temperature Reverse Transcription) conditions:

Step Time Temperature No. of Cycles
dT20
Primer annealing 37°C 10~30 sec 1, 5, 10, or 15
cDNA synthesis 50°C 4 min
Melting secondary structure & cDNA synthesis 55°C 30 sec
Heat inactivation 95°C 5 min 1

Primer set: Human GAPDH and myc set
Lane M: 1 kb DNA Ladder
Lane1: 10 ng Human Total RNA from HeLa Cell
Lane 2: 1 ng Human Total RNA from HeLa Cell
Lane 3: 100 pg Human Total RNA from HeLa Cell
Lane 4: 10 pg Human Total RNA from HeLa Cell


Figure 5. Comparison of amplification results between Bioneer RocketScript™ Cycle RT PreMix and competitor RTases
All cDNAs were amplified with AccuPower® Hotstart PCR Premix (K-5050) from Bioneer
Primer set: human Myc498 bp set
Lane M: 1 kb DNA Ladder
Lane1: 10 ng Human total RNA from HeLa Cell
Lane 2: 1 ng Human total RNA from HeLa Cell
Lane 3: 100 pg Human total RNA from HeLa Cell
Lane 4: 10 pg Human total RNA from HeLa Cell



 

]]>
Manual
AccuPower® RocketScript Cycle RT PreMix


MSDS
AccuPower® RocketScript Cycle RT PreMix


Brochure
• AccuPower® RocketScript Cycle RT PreMix - 2011 Brochure


Quality Assurance
Bioneer is the holder of Quality Management System Certificates for the following standards.

ISO 9001:2008 - certificate

EN ISO 13485:2003 / AC:2009 - certificate

]]>