• AccuTarget™ Real-Time PCR Primers Library


Predesigned and validated Real-Time PCR primers for measuring siRNA knockdown results

The AccuTarget™ Human Validated Real-Time PCR Primer Library is comprised of highly specific and sensitive Real-Time primer sets that are bioinformatically designed and validated based on the human genome. The Real-Time PCR Primer Library consists of 11,154 primer sets validated in Real-Time PCR and used to measure siRNA knockdown results


Features and Benefits

 

  • In ready-to-ship format: 11,154 human genes specific primers
  • All Primers pre-validated: QC tested via MALDI-TOF mass spectrometer
  • Competitive pricing: Great value for your research dollar

]]>
AccuTarget™ Human Validated Real-Time PCR Primer Library is comprised of highly specific and sensitive Real-Time primer sets that are bioinformatically designed and validated based on the human genome. The Real-Time PCR Primer Library consists of 11,154 primer sets validated in Real-Time PCR with SYBR Green detection using Exicycler™ 96 and AccuPower GreenStar™ qPCR PreMix. The Library is categorized by gene function and pathway. The Library guarantees the most specific and sensitive Real-Time PCR result when used with AccuPower GreenStar PCR PreMix (Not available in the US).



Figure 1. Real-Time PCR validation test of Human Oxidoreductase using AccuTarget™ Human Oxidoreductase Real-Time PCR Primer Set (A; Amplification curve, B; Melting curve analysis) Real-Time PCR reaction for AccuTarget™ Human Oxidoreductase Real-Time PCR Primer Set was tested using Exicycler 96 Real-Time Quantitative Thermal Block (Cat. No. A-2060) and AccuPower GreenStar PCR PreMix (Cat. No. K-6210). cDNA template was reverse-transcribed from QPCR Human Reference Total RNA 30 ng and reaction condition was 95°C 10 minutes, 1 cycle and 95°C 10 seconds, 58°C 25 seconds, 72°C 30 seconds, 41 cycles.



Figure 2. Real-Time PCR validation test of hHPRT1 and hSLC12A1 genes (A; Amplification curve of hHPRT1, B; Melting curve analysis of hHPRT1, C; Amplification curve of hSLC12A1, D; Melting curve analysis of hSLC12A1) Real-Time PCR for hHPRT1 Primer Set and hSLC12A1 Primer Set were tested using Exicycler 96 Real-Time Quantitative Thermal Block (Cat. No. A-2060) and AccuPower GreenStar PCR PreMix (Cat. No. K-6210). cDNA template was reverse-transcribed from qPCR Human Reference Total RNA 30 ng (60 ng) and reaction condition was 95°C 10 minutes, 1 cycle and 95°C 10 seconds, 58°C 25 seconds, 72°C 30 seconds, 41 cycles.               



Figure 3. Real-Time PCR sensitivity test for detection of hPGK1 (Phosphoglycerate Kinase 1; Housekeeping gene) gene using AccuTarget™ hPGK1 primer set. (A; Amplification curve, B; Standard curve analysis, C; Melting curve analysis, 1; 100 ng QPCR Human Reference Total RNA, 2; 10 ng QPCR Human Reference Total RNA, 3; 1 ng QPCR Human Reference Total RNA, 4; 100 pg QPCR Human Reference Total RNA, 5; 10 pg QPCR Human Reference Total RNA, N; NTC [No Template Control]) Real-Time PCR reaction for hPGK1 primer set was tested using Exicycler 96 Quantitative Real-Time Thermal Block (Cat. No. A-2060), AccuPower GreenStar PCR PreMix (Cat. No. K-6210) and Opticon (BioRad). cDNA template was reverse-transcribed from QPCR Human Reference Total RNA 400ng (serial dilution; 100 ng, 10 ng, 100 pg, 10 pg) and reaction condition was 95°C 10 minutes, 1 cycle and 95°C 10 seconds, 58°C 25 seconds, 72°C 30 seconds, 41 cycles.



Figure 4. Comparison of Real-Time PCR reproducibility test of hPGK1 (Phosphoglycerate Kinase 1; Housekeeping gene) gene detecting primer set from Bioneer and competitors. [A, B & C: AccuTarget™ hPGK1 Primer Set, D, E & F; Competitor Q hPGK1 primer set, A & D; Amplification curve, B & E; Standard curve analysis, C & F: Melting curve analysis, 1; 100 ng QPCR Human Reference Total RNA, 2; 10 ng QPCR Human Reference Total RNA, 3; 1 ng QPCR Human Reference Total RNA, 4; 100 pg QPCR Human Reference Total RNA, 5; 10 pg QPCR Human Reference Total RNA, N; NTC (No Template Control)] Real-Time PCR reaction for hPGK1Primer Set was tested using Opticon (BioRad) and AccuPower GreenStar qPCR PreMix (Cat. No. K-6210). cDNA template was reverse-transcribed from QPCR Human Reference Total RNA 400ng (serial dilution; 100 ng, 10 ng, 100 pg, 10 pg) and reaction condition was 95°C 10 minutes, 1 cycle and 95°C 10 seconds, 58°C 25 seconds, 72°C 30 seconds, 41 cycles.




Figure 5. QC test for AccuTarget™ Validated Real-Time PCR primer Library for Human Quality control of Real-Time PCR primer Library was tested using MALDI-TOF instrument that analyzes oligo mass.











]]>
Mamual

qPCR User Manual


Brochure

siRNA Products and services


Quality Assurance

Bioneer is the holder of Quality Management System Certificates for the following standards.

ISO 9001:2008 - certificate

EN ISO 13485:2003 / AC:2009 - certificate

EC Directive 98/79/EC - certificate

]]>